{"product_id":"cylindrical-cell-electrolyte-filling-vacuum-standing-machine","title":"Cylindrical Cell Electrolyte Filling and Vacuum Standing Machine","description":"\u003cp\u003eThe FL-ZY1865 is a \u003cstrong\u003ecylindrical cell electrolyte filling and vacuum standing machine\u003c\/strong\u003e that dispenses first, then moves the fixture into the vacuum standing position. The PLC-controlled X\/Y stage positions each cell below the fill needle, then transfers the filled cells to the chamber. The operator loads and unloads the fixture. Final cell sealing is a separate operation.\u003c\/p\u003e\n\u003cfigure style=\"margin:1.5rem 0\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/9586\/4767\/files\/cylindrical-electrolyte-filling-vacuum-standing-machine.webp?v=1794401824\" alt=\"Cylindrical cell electrolyte filling and vacuum standing machine with touchscreen and cell fixture\" width=\"1254\" height=\"1254\" loading=\"lazy\" style=\"display:block;width:100%;height:auto;max-width:600px\"\u003e\u003cfigcaption\u003eRepresentative illustration of the cylindrical cell filling and vacuum standing station.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel \/ SKU\u003c\/th\u003e\n\u003ctd\u003eFL-ZY1865\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFixture positions\u003c\/th\u003e\n\u003ctd\u003e10; sequential filling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCell formats\u003c\/th\u003e\n\u003ctd\u003e14450, 14500, 18650, 21700 or 4680 with matched tooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl\u003c\/th\u003e\n\u003ctd\u003ePLC touchscreen; configurable fill count, dose and standing time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNominal dosing accuracy\u003c\/th\u003e\n\u003ctd\u003e±1%; verify at the target dose and with the selected liquid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChamber opening height\u003c\/th\u003e\n\u003ctd\u003e115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEquipment dimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e640 × 400 × 725 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApproximate equipment weight\u003c\/th\u003e\n\u003ctd\u003e90 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated electrical power\u003c\/th\u003e\n\u003ctd\u003e500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDispense mass\u003c\/th\u003e\n\u003ctd\u003eAbove 0.2 g per cell; adjustable. Confirm the usable dose with the actual electrolyte.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDispense speed\u003c\/th\u003e\n\u003ctd\u003eNominal 3 mL\/s, adjustable; maximum 6 mL\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum reference\u003c\/th\u003e\n\u003ctd\u003eNominally around −98 kPa gauge; confirm reference and achieved pressure for the actual cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTimers\u003c\/th\u003e\n\u003ctd\u003eAdjustable evacuation and vacuum standing times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLiquid tubing\u003c\/th\u003e\n\u003ctd\u003e6 mm nominal tubing; verify fittings and wetted materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandard power input\u003c\/th\u003e\n\u003ctd\u003eAC 220 V \/ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePneumatic supply\u003c\/th\u003e\n\u003ctd\u003eDry, filtered, regulated supply above approximately 0.39 MPa (4 kgf\/cm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFill First, Then Vacuum Stand\u003c\/h2\u003e\n\u003cp\u003eThis model applies vacuum after electrolyte dispensing. If your process requires chamber evacuation before filling, see the \u003ca href=\"\/products\/vacuum-electrolyte-filling-standing-machine\"\u003evacuum-first electrolyte filling and standing system\u003c\/a\u003e. For the separate closure step, see the \u003ca href=\"\/products\/automatic-cylindrical-cell-sealing-machine\"\u003eautomatic cylindrical cell sealing machine\u003c\/a\u003e and confirm tooling independently.\u003c\/p\u003e\n\u003cp\u003eIf the process requires only one step, compare our \u003ca href=\"\/products\/ceramic-plunger-pump-electrolyte-filling\"\u003eceramic plunger dosing pump\u003c\/a\u003e or \u003ca href=\"\/products\/vacuum-standing-box-battery-electrolyte-wetting\"\u003estandalone vacuum standing box\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eRequest a Quote\u003c\/h2\u003e\n\u003cp\u003eProvide your cell drawing, target dose, fixture format, vacuum dwell, utility requirements and destination. Confirm the needle and fixture, packed dimensions, vacuum pump scope and compatible wetted materials. If your site requires AC 110 V \/ 60 Hz, request configuration confirmation. Check glovebox clearances, process gas and exhaust arrangement before ordering.\u003c\/p\u003e","brand":"Flux Battery Hub","offers":[{"title":"Default Title","offer_id":67932387868863,"sku":"FL-ZY1865","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/9586\/4767\/files\/cylindrical-electrolyte-filling-vacuum-standing-machine.webp?v=1794401824","url":"https:\/\/fluxbatteryhub.com\/products\/cylindrical-cell-electrolyte-filling-vacuum-standing-machine","provider":"Flux Battery Hub","version":"1.0","type":"link"}