{"product_id":"pouch-cell-hot-press-short-circuit-tester","title":"Pouch Cell Hot Press and Short Circuit Tester","description":"\u003cp\u003eThis pouch cell hot press and short circuit tester combines heated flat pressing with insulation-resistance screening in one laboratory station. Pneumatic upper and lower platens apply adjustable heat and compression to shape cell cores and develop thickness consistency. The integrated electrical test provides a separate screening function for insulation defects during cell assembly research.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/9586\/4767\/files\/pouch-cell-hot-press-short-circuit-tester.webp?v=1794320954\" alt=\"Pouch cell hot press and short circuit tester with heated platens, protective enclosure and light curtain — representative illustration\" width=\"1254\" height=\"1254\" loading=\"lazy\" style=\"display:block;width:100%;max-width:600px;height:auto;margin:24px auto;\"\u003e\u003cfigcaption\u003eRepresentative equipment illustration adapted from the product reference. Dimensions and final controls vary with the selected configuration.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003ch2\u003eCompare Cell Capacity and Machine Size\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFL-DRY200\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFL-DRY300\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFL-DRY350\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum cell dimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e200 × 200 × 70 mm\u003c\/td\u003e\n\u003ctd\u003e300 × 300 × 70 mm\u003c\/td\u003e\n\u003ctd\u003e350 × 350 × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMachine dimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e350 × 320 × 550 mm\u003c\/td\u003e\n\u003ctd\u003e450 × 420 × 650 mm\u003c\/td\u003e\n\u003ctd\u003e500 × 470 × 650 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated power\u003c\/th\u003e\n\u003ctd\u003e2 kW\u003c\/td\u003e\n\u003ctd\u003e3 kW\u003c\/td\u003e\n\u003ctd\u003e3 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApproximate equipment weight\u003c\/th\u003e\n\u003ctd\u003e180 kg\u003c\/td\u003e\n\u003ctd\u003e180 kg\u003c\/td\u003e\n\u003ctd\u003e180 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eChoose a model against the full cell drawing, including tabs, fixtures and required clearances. Maximum cell dimensions do not specify platen dimensions or guarantee compatibility with every cell construction.\u003c\/p\u003e\n\n\u003ch2\u003eSelect Model and Power Supply\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pouch-cell-hot-press-short-circuit-tester?variant=67924695777471\"\u003eSelect FL-DRY200 \/ AC 220V \/ 50Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pouch-cell-hot-press-short-circuit-tester?variant=67924695810239\"\u003eSelect FL-DRY200 \/ AC 110V \/ 60Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pouch-cell-hot-press-short-circuit-tester?variant=67924695843007\"\u003eSelect FL-DRY300 \/ AC 220V \/ 50Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pouch-cell-hot-press-short-circuit-tester?variant=67924695875775\"\u003eSelect FL-DRY300 \/ AC 110V \/ 60Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pouch-cell-hot-press-short-circuit-tester?variant=67924695908543\"\u003eSelect FL-DRY350 \/ AC 220V \/ 50Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pouch-cell-hot-press-short-circuit-tester?variant=67924695941311\"\u003eSelect FL-DRY350 \/ AC 110V \/ 60Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSelect one factory electrical version, then use Request a Quote. Both voltage options are available for each model.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSingle-station hot press shaping with adjustable temperature and pneumatic loading.\u003c\/li\u003e\n\u003cli\u003eDigital display of temperature settings and operating values.\u003c\/li\u003e\n\u003cli\u003eManual and automatic test modes with automatic short-circuit alarm.\u003c\/li\u003e\n\u003cli\u003eIntegrated insulation-resistance and leakage-current measurement functions.\u003c\/li\u003e\n\u003cli\u003eLight-curtain protection and protective enclosure around the moving press area.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeating range\u003c\/th\u003e\n\u003ctd\u003eAmbient temperature to 130°C, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature control reference\u003c\/th\u003e\n\u003ctd\u003e±4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNominal pressing load range\u003c\/th\u003e\n\u003ctd\u003e0–900 kgf (approximately 0–8.83 kN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorking travel\u003c\/th\u003e\n\u003ctd\u003e0–80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAdjustable DC test voltage\u003c\/th\u003e\n\u003ctd\u003e0–500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum measurable leakage current\u003c\/th\u003e\n\u003ctd\u003e50 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum insulation-resistance measurement\u003c\/th\u003e\n\u003ctd\u003e199 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShort-circuit indication\u003c\/th\u003e\n\u003ctd\u003eAutomatic alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTest modes\u003c\/th\u003e\n\u003ctd\u003eManual and automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompressed-air supply\u003c\/th\u003e\n\u003ctd\u003e0.5–0.8 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical supply\u003c\/th\u003e\n\u003ctd\u003eAC 220V \/ 50Hz or AC 110V \/ 60Hz — select one factory version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe pressing-load figure is a force rating, not pressure per unit cell area. The temperature-control reference is not a verified temperature-uniformity specification over the full platen. The 50 µA value is the maximum measurable leakage current, not a universal pass\/fail threshold. Test duration, contact arrangement, trip settings and calibration requirements must be confirmed for the configured system.\u003c\/p\u003e\n\u003ch2\u003eHot Press Shaping and Insulation Screening\u003c\/h2\u003e\u003cp\u003eUse this equipment to develop flat-press shaping conditions for compatible pouch cell cores and to screen insulation using an approved test procedure. Set temperature, load, dwell and electrical test limits for the actual electrode stack, separator and assembly stage. Verify thickness and insulation results against your own acceptance criteria; pressing does not guarantee elimination of internal shorts.\u003c\/p\u003e\n\u003cp\u003eThis is not a charge\/discharge formation cycler, a pouch-film heat sealer, or a destructive external short-circuit abuse-test system. An insulation test alone does not certify battery safety. Before applying a DC insulation test, confirm specimen condition and the test-contact arrangement; do not apply the high-voltage insulation output across a charged cell or assembled battery without an explicitly validated procedure and suitable protection.\u003c\/p\u003e\n\u003ch2\u003eUtilities and Operator Protection\u003c\/h2\u003e\u003cp\u003eProvide both compressed air and the selected electrical supply. The 110V \/ 60Hz and 220V \/ 50Hz versions are factory alternatives, not automatically switching dual-voltage input. Confirm nameplate current, plug and circuit requirements for the 2 or 3 kW model before installation.\u003c\/p\u003e\u003cp\u003eOperate only with trained personnel, the enclosure and light curtain in place, and hands clear of hot platens and moving guides. Dual-button start is specified for FL-DRY300 and FL-DRY350; confirm the final control arrangement for FL-DRY200. Isolate electricity and compressed air, release stored pressure and allow the platens to cool before maintenance. Inspect guards and fasteners and keep the platen surfaces clean.\u003c\/p\u003e\n\u003ch2\u003eRelated Pouch Cell Assembly Equipment\u003c\/h2\u003e\u003cp\u003eFor upstream electrode assembly, compare the \u003ca href=\"\/products\/semi-automatic-z-fold-electrode-stacking-machine\"\u003eZ-fold electrode stacking machine\u003c\/a\u003e and \u003ca href=\"\/products\/manual-battery-electrode-winding-machine\"\u003ebattery electrode winding machine\u003c\/a\u003e. For a separate packaging step, see the \u003ca href=\"\/products\/fl-sfz-pouch-cell-top-side-heat-sealing-machine\"\u003epouch cell top and side heat sealer\u003c\/a\u003e. Explore \u003ca href=\"\/collections\/pouch-cell-preparation\"\u003epouch cell preparation equipment\u003c\/a\u003e to match each station to your process.\u003c\/p\u003e\n\u003ch2\u003eRequest a Quote\u003c\/h2\u003e\u003cp\u003eSend your cell dimensions and assembly stage, required pressing conditions, insulation-test method, preferred model and electrical supply, quantity and delivery destination. We will confirm the suitable configuration and provide a written quotation.\u003c\/p\u003e","brand":"Flux Battery Hub","offers":[{"title":"FL-DRY200 \/ AC 220V \/ 50Hz","offer_id":67924695777471,"sku":"FL-DRY200","price":0.0,"currency_code":"USD","in_stock":false},{"title":"FL-DRY200 \/ AC 110V \/ 60Hz","offer_id":67924695810239,"sku":"FL-DRY200-110V","price":0.0,"currency_code":"USD","in_stock":false},{"title":"FL-DRY300 \/ AC 220V \/ 50Hz","offer_id":67924695843007,"sku":"FL-DRY300","price":0.0,"currency_code":"USD","in_stock":false},{"title":"FL-DRY300 \/ AC 110V \/ 60Hz","offer_id":67924695875775,"sku":"FL-DRY300-110V","price":0.0,"currency_code":"USD","in_stock":false},{"title":"FL-DRY350 \/ AC 220V \/ 50Hz","offer_id":67924695908543,"sku":"FL-DRY350","price":0.0,"currency_code":"USD","in_stock":false},{"title":"FL-DRY350 \/ AC 110V \/ 60Hz","offer_id":67924695941311,"sku":"FL-DRY350-110V","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/9586\/4767\/files\/pouch-cell-hot-press-short-circuit-tester.webp?v=1794320954","url":"https:\/\/fluxbatteryhub.com\/products\/pouch-cell-hot-press-short-circuit-tester","provider":"Flux Battery Hub","version":"1.0","type":"link"}