{"product_id":"vacuum-standing-box-battery-electrolyte-wetting","title":"Vacuum Standing Box for Battery Electrolyte Wetting","description":"\u003cp\u003eThis vacuum standing box supports electrolyte wetting in lithium-ion battery laboratory workflows after electrolyte filling. Controlled evacuation and programmable standing periods help remove trapped air and promote electrolyte penetration into the electrode assembly. The split chamber and control-box design supports compatible pouch cell and cylindrical cell research setups.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/9586\/4767\/files\/vacuum-standing-box-electrolyte-wetting.webp?v=1794240302\" alt=\"Vacuum standing chamber and separate controller for pouch and cylindrical battery electrolyte wetting — illustration\" width=\"1254\" height=\"1254\" loading=\"lazy\" style=\"display:block;width:100%;max-width:600px;height:auto;margin:24px auto;\"\u003e\u003cfigcaption\u003eEquipment illustration adapted from the machine reference image; final configuration may vary.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003ch2\u003eVacuum-Assisted Battery Electrolyte Wetting\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProgrammable standing time and multi-stage cycling for process-development trials.\u003c\/li\u003e\n\u003cli\u003ePneumatically raised and lowered upper chamber with guided motion.\u003c\/li\u003e\n\u003cli\u003eObservation window for viewing the chamber during the process.\u003c\/li\u003e\n\u003cli\u003eSeparate working chamber and controller for flexible laboratory integration.\u003c\/li\u003e\n\u003cli\u003e320 × 220 × 175 mm internal chamber for compatible cells and fixtures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUse after electrolyte dosing and before the next sealing or assembly step required by your cell process. This equipment is a vacuum standing chamber, not an electrolyte metering pump, heat sealer, vacuum drying oven or formation cycler. Wetting results depend on electrolyte properties, electrode structure, cell geometry and the validated pressure\/time sequence.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel \/ SKU\u003c\/th\u003e\n\u003ctd\u003eFL-JZ300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eVacuum-assisted electrolyte wetting after filling, for compatible pouch and cylindrical cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInternal chamber dimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e320 × 220 × 175 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStanding \/ hold time\u003c\/th\u003e\n\u003ctd\u003e0–9,999 seconds, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum capability\u003c\/th\u003e\n\u003ctd\u003eApproximately −95 kPa gauge with a suitable external vacuum pump; actual achievable pressure depends on the pump, connections and operating conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReference operating vacuum\u003c\/th\u003e\n\u003ctd\u003eApproximately −90 kPa gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum retention reference\u003c\/th\u003e\n\u003ctd\u003ePressure rise no greater than approximately 1 kPa over 1 minute under the specified sealed-chamber test conditions; confirm test conditions at quotation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChamber material\u003c\/th\u003e\n\u003ctd\u003eAluminum alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eAC 220V \/ 50Hz or AC 110V \/ 60Hz — select one factory version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated electrical power\u003c\/th\u003e\n\u003ctd\u003e100 W (machine only; external vacuum pump is separate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePneumatic supply pressure\u003c\/th\u003e\n\u003ctd\u003e0.5–0.8 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChamber \/ motion unit dimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003eApproximately 500 × 350 × 630 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl unit dimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003eApproximately 460 × 350 × 340 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTotal equipment weight\u003c\/th\u003e\n\u003ctd\u003eApproximately 50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum pump\u003c\/th\u003e\n\u003ctd\u003eNot included; provide a compatible external vacuum source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eSafety light curtain and protective enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eVacuum values above are gauge pressures relative to ambient, not absolute pressure. The vacuum pump must be selected for the required pressure, evacuation time and electrolyte-vapor compatibility. Do not treat maximum vacuum capability as the recommended setting for every electrolyte.\u003c\/p\u003e\n\u003ch2\u003eGlovebox and Utility Requirements\u003c\/h2\u003e\n\u003cp\u003eThe split layout allows the chamber to be considered for glovebox installation, subject to verification of the access opening, internal clearance, feedthroughs and exhaust routing. The chamber-unit dimensions are larger than the usable internal chamber dimensions. Confirm physical fit before ordering.\u003c\/p\u003e\n\u003cp\u003eWhen operated inside a glovebox, the pneumatic drive must use the same compatible working gas as the glovebox atmosphere at 0.5–0.8 MPa. Do not introduce ordinary compressed air into an inert glovebox. Confirm the vacuum pump, exhaust handling, seals and wetted materials for your electrolyte and site procedures. No universal chemical compatibility or explosion-proof rating is claimed.\u003c\/p\u003e\n\u003ch2\u003eChoose the Electrical Version\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/vacuum-standing-box-battery-electrolyte-wetting?variant=67914027139263\"\u003eSelect AC 220V \/ 50Hz — FL-JZ300\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/vacuum-standing-box-battery-electrolyte-wetting?variant=67914027172031\"\u003eSelect AC 110V \/ 60Hz — FL-JZ300-110V\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable as AC 220V \/ 50Hz or AC 110V \/ 60Hz. Choose one factory configuration in your quote request; this is not an automatic dual-voltage input. Specify any separate electrical requirements for the external vacuum pump.\u003c\/p\u003e\n\u003ch2\u003eRelated Battery Assembly Equipment\u003c\/h2\u003e\n\u003cp\u003eExplore \u003ca href=\"\/collections\/pouch-cell-preparation\"\u003epouch cell preparation equipment\u003c\/a\u003e and \u003ca href=\"\/collections\/cylindrical-cell-preparation\"\u003ecylindrical cell preparation equipment\u003c\/a\u003e for your cell format. For a pouch cell workflow, compare the \u003ca href=\"\/products\/fl-sck-pouch-cell-aluminum-film-forming-machine\"\u003ealuminum laminated film cup forming machine\u003c\/a\u003e upstream and the \u003ca href=\"\/products\/fl-yf-pouch-cell-vacuum-pre-sealing-machine\"\u003evacuum pre-sealing machine\u003c\/a\u003e for the subsequent sealing stage, as required by your process.\u003c\/p\u003e\n\u003ch2\u003eRequest a Quote\u003c\/h2\u003e\n\u003cp\u003eSend the cell format and dimensions, batch quantity and fixture layout, electrolyte compatibility requirements, target vacuum and hold sequence, available vacuum source, preferred electrical version, glovebox installation details and delivery destination. We will confirm the configured equipment, included accessories and commercial terms by email.\u003c\/p\u003e","brand":"Flux Battery Hub","offers":[{"title":"AC 220V \/ 50Hz","offer_id":67914027139263,"sku":"FL-JZ300","price":0.0,"currency_code":"USD","in_stock":false},{"title":"AC 110V \/ 60Hz","offer_id":67914027172031,"sku":"FL-JZ300-110V","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/9586\/4767\/files\/vacuum-standing-box-electrolyte-wetting.webp?v=1794240302","url":"https:\/\/fluxbatteryhub.com\/products\/vacuum-standing-box-battery-electrolyte-wetting","provider":"Flux Battery Hub","version":"1.0","type":"link"}