The FL-NMP-1 and FL-NMP-2 NMP solvent treatment systems handle water-soluble solvent vapors in exhaust from battery electrode coating and drying. Select a nominal exhaust-treatment capacity of 600 or 1,200 m³/h to match the coater exhaust load. SUS304 stainless-steel contact surfaces and an external exhaust-duct connection support integration into a laboratory or pilot electrode-processing workflow.

Electrical configuration: AC 220 V / 50 Hz or AC 110 V / 60 Hz, selected when ordering and configured before shipment. These are alternative factory configurations, not an automatically switching dual-voltage input. Final wiring, current rating and circuit requirements are confirmed with the quotation.

FL-NMP solvent treatment system for battery electrode coating exhaust
Representative FL-NMP series image; final configuration is confirmed with quotation.

Compare FL-NMP Solvent Treatment Models

Specification FL-NMP-1 FL-NMP-2
Nominal treatment airflow 600 m³/h 1,200 m³/h
Rated power 1.5 kW 3 kW
External dimensions 1,100 × 800 × 1,800 mm 1,100 × 800 × 1,800 mm
Water tanks 2 × 50 L Two-stage water-bath treatment; tank capacities confirmed with quotation
Water-pump flow 45 L/min Confirmed with quotation
Fan static pressure 1,200 Pa Confirmed with quotation
Water make-up Confirm selected configuration Automatic water make-up design

Select a Model and Power Supply for Your Quote

Key Features

  • Continuous exhaust treatment for water-soluble solvent vapors generated during electrode drying.
  • SUS304 stainless-steel contact material for the wet-treatment system.
  • FL-NMP-1 dual 50 L water tanks, 45 L/min pump flow and 1,200 Pa fan static-pressure specification.
  • FL-NMP-2 two-stage water-bath treatment with an integrated suction fan and automatic water make-up.
  • External exhaust duct connection for installation alongside compatible coating and drying equipment.

Common Technical Specifications

Operating mode Continuous
Target stream Exhaust gas containing compatible water-soluble solvent vapors, including NMP
Maximum inlet gas temperature 150°C
Recovery-rate reference ≥80%; application-specific verification required
Contact material SUS304 stainless steel
Ambient operating temperature 0–40°C
Exhaust outlet Connection to external ducting
Installation environment No significant surrounding vibration or impact sources
Power supply options AC 220 V / 50 Hz or AC 110 V / 60 Hz; factory-configured choice

Coating-Dryer Exhaust Integration

Match the system to the actual exhaust volume, solvent composition and concentration, inlet temperature, particulate loading and duct resistance. The ≥80% recovery figure is a selection reference rather than a guaranteed result for every installation. Confirm the applicable test conditions and acceptance criteria before ordering; it is not a certification of emission-limit compliance or a recovered-solvent purity specification.

Specify the water supply, make-up arrangement, drainage, maintenance access and exhaust route during system design. Treatment liquid requires suitable collection and handling. Hazardous-area suitability, explosion-protection certification and compatibility with other solvents are not established by this listing and must be reviewed for the intended installation.

Related Battery Electrode Equipment

Explore our automatic film coater for battery electrode preparation and cell making equipment and tools. The film coater is a related process tool, not a confirmed direct exhaust connection; confirm your actual dryer and duct interface before selecting this treatment system. See lithium-ion battery research supplies for the wider laboratory workflow.

Request a Quote

Send your preferred FL-NMP model and electrical option, coater/dryer model, exhaust airflow, solvent type and concentration, inlet temperature, duct layout, available water and drainage, installation location, quantity and destination country. FluxBatteryHub will confirm the configuration and provide pricing by email.

Vollständige Details anzeigen

Laborangebot anfordern

Für institutionelle Bestellungen, Sonderkonfigurationen, größere Mengen oder schriftlich bestätigte Versandbedingungen geben Sie bitte unten die erforderlichen Angaben ein. Wir antworten, bevor eine Bestellung ausgelöst wird.

Produkt: NMP Solvent Treatment System for Battery Coating | 600 & 1200 m³/h
SKU: FL-NMP-2-110V

Das Absenden dieses Formulars löst keine Bestellung aus und bestätigt weder Verfügbarkeit noch Preis oder Liefertermin. DDP-Versand ist für die meisten von uns bedienten Ziele enthalten. Für abgelegene, eingeschränkte oder nicht unterstützte Ziele können abweichende Bedingungen gelten; diese bestätigen wir vor der Auftragsabwicklung.