This manual hydraulic press series supports laboratory battery-material sample preparation, including powder pellet pressing and flat pressing or shaping. A hand-operated hydraulic mechanism applies load while the built-in gauge provides a hydraulic-pressure reference. Choose the tooling configuration for the intended task: a Ø16.2 mm powder pellet die or Ø53 mm pressing tooling. The two models are related presses, not interchangeable specifications.
Select Pressing Configuration
Choose the configuration, then use Request a Quote. Confirm the sample and required load before ordering.
Choose the Right Pressing Configuration
| Specification | FL-YFB160 — Powder Pellet Press | FL-YP180 — Material / Tablet Press |
|---|---|---|
| Standard tooling diameter | Ø16.2 mm powder pellet die | Ø53 mm pressing die |
| Primary selection focus | Small powder pellets for material sample preparation | Flat pressing and shaping of laboratory materials |
| Pellet thickness adjustment | 0–3 mm nominal range | Not specified |
| Pressing travel | Not specified | 30 mm |
| Rated pressing load | 2 metric ton-force (approximately 19.6 kN) | Not specified — confirm required load before ordering |
| Hydraulic gauge operating reference | No reference setting specified | Approximately 150 kgf/cm²; process reference, not maximum rating |
| Tool-face flatness | Not specified | 0.005 mm |
| External dimensions (L × W × H) | 280 × 210 × 355 mm | 223 × 170 × 355 mm |
| Equipment weight | 25 kg | 25 kg |
| Operation | Manual hydraulic; no electrical supply required | Manual hydraulic; no electrical supply required |
For FL-YP180, approximately 150 kgf/cm² (about 14.7 MPa) is a hydraulic gauge reference, not the applied force in tonnes or pressure on the specimen. A cylinder calibration and actual contact area are needed to relate those quantities. Do not transfer the FL-YFB160 2-ton rating to FL-YP180. The 30 mm value is press travel, not finished-sample thickness; 0.005 mm describes tool-face flatness, not guaranteed sample flatness.
Key Features
- Hand-operated hydraulic loading with a built-in pressure gauge.
- Linear-guided pressing structure and compact benchtop format.
- Dedicated standard tooling for powder pellet or flat-pressing applications.
- Manual pressure-release control for opening the tooling after unloading.
- Custom tooling dimensions can be discussed against the sample drawing.
Model Images


Powder Pellet Pressing versus Flat Pressing
Choose FL-YFB160 when the required sample matches the standard Ø16.2 mm powder pellet die and nominal 0–3 mm thickness-adjustment range. Achievable pellet thickness, integrity and density depend on the powder, fill mass, binder, loading and dwell conditions. The stated range is not a thickness tolerance or a promise that every material can be compacted.
Choose FL-YP180 for the Ø53 mm pressing-tool configuration and 30 mm travel. Confirm whether the application needs flat faces, a powder-confining die, an ejection arrangement or other tooling; a Ø53 mm tool dimension alone does not guarantee a Ø53 mm free-standing pellet. Supply the intended load and sample drawing so the press and die ratings can be checked together.
These are sample-preparation presses, not coin-cell crimpers, electrode rolling calenders or heated presses. They do not provide charge/discharge cycling or certified mechanical testing. Glovebox installation requires confirmation of transfer clearances, handling access, materials compatibility and hydraulic-fluid containment.
Handling and Maintenance
Keep the hydraulic press upright; do not lay it on its side or invert it, because hydraulic oil may leak. Keep hands clear of the tooling and moving guides, use appropriate eye protection and qualified tooling, and release pressure fully before removing the specimen or servicing the unit. Do not perform an unloaded dry press with FL-YFB160. Never exceed the configured press or die rating.
Keep forming surfaces and guides clean, handle dies carefully and use cleaning or lubrication methods compatible with the material and laboratory environment. Inspect hydraulic-fluid level, gauge condition, fittings, leaks and fasteners regularly. Do not assume every powder is compatible with alcohol cleaning or every hydraulic oil is acceptable in a glovebox.
Related Battery Sample-Preparation Tools
For cutting electrode or separator discs instead of compacting material, see the manual coin cell disc punch. For sealing an assembled coin cell, use a dedicated hydraulic coin cell crimper. Browse battery preparation equipment and tools to choose the correct process station.
Request a Quote
Send the sample material, target diameter and thickness, required load, tooling geometry, quantity and delivery destination. Indicate the preferred pressing configuration and any glovebox constraints. We will confirm the suitable press and die arrangement and provide a written quotation.
Share

Request a Lab Quote
For institutional purchase orders, non-standard configurations, larger quantities or written shipping terms, send the details below. We will reply before anything is ordered.
Product: Manual Hydraulic Press for Battery Materials
SKU: FL-YP180
Browse Related Research Categories
-
Battery Separators
Compare battery separator films, membranes and pre-cut discs for laboratory cells. Options...
-
Coin Cell Components
Compare coin cell cases, spacers and springs for laboratory battery assembly. The...
-
Current Collectors & Foils
Browse current collectors and metal substrates for laboratory electrode preparation, including copper...
-
Conductive Additive
Compare conductive carbon blacks and graphite for laboratory battery electrode formulations. Grades...