Pneumatic Coin Cell Crimping Machine for CR20XX Cells
Pneumatic Coin Cell Crimping Machine for CR20XX Cells
SKU:FL-QF150
- Formal Quotes & POs
- DDP to Most Destinations
- Return Policy Available
This pneumatic coin cell crimping machine seals laboratory CR20-series cells using regulated gas pressure and a mechanical control valve. It requires no electrical supply and supports external exhaust routing for glovebox installations. The standard crimping configuration is intended for battery materials research, sample preparation and small-batch trials; other cell formats require the appropriate optional tooling.

Key Features
- Purely pneumatic operation with a manual directional valve.
- Lower-die positioning ring and adjustable height stop for setting the crimping limit.
- Upper-die screw-and-spring ejection mechanism to assist release of a stuck cell.
- Gas supply from a regulated argon or nitrogen cylinder, or compressed air where appropriate.
- Dedicated exhaust outlet for routing spent gas outside the glovebox.
- Standard CR20-series crimping tooling, with optional crimping and disassembly dies.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model / SKU | FL-QF150 |
| Drive and control | Pneumatic; manually operated control valve |
| Electrical supply | Not required |
| Specified gas-supply range | 0.6–0.8 MPa |
| Recommended regulated operating pressure | 0.7 MPa |
| Pressure-control limit | 1 MPa; not a recommended supply setting |
| Gas consumption per crimp | Approximately 480 mL; reference conditions to be confirmed |
| Crimping stroke | 30 mm |
| Standard crimping tooling | CR20-series coin cells |
| Optional crimping tooling | CR16, CR24 and CR30 series; confirm the exact case and required die components |
| Optional disassembly tooling | CR16, CR20, CR24 and CR30 series — not included as standard |
| Exhaust connection | Dedicated outlet; external routing via suitable KF40-type components or other configured fittings |
| Installation dimensions (L × W × H) | 290 × 205 × 330 mm |
| Approximate weight | 25 kg |
| Structural material | High-strength chromium steel with plated / coated surface treatment |
Gas pressure is not crimping force or pressure on the cell. No kgf, kN or cell-contact-pressure rating is specified here. Use the stated 0.6–0.8 MPa supply range and the recommended 0.7 MPa operating pressure; the 1 MPa control limit is not permission to increase the inlet supply beyond its specified range. Confirm pressure-control calibration and gas-consumption reference conditions for the configured unit.
Glovebox Gas Supply and External Exhaust
For glovebox use, select the gas to match the cell chemistry and glovebox atmosphere, and route the exhaust through an appropriate sealed feedthrough. Compressed air is not recommended inside a controlled-atmosphere glovebox. Argon or nitrogen must also be selected for compatibility with the particular materials and process; they are not interchangeable for every application.
KF40-type components describe a possible exhaust-routing arrangement, not a promise that a complete feedthrough, regulator, cylinder or gas line is included. Specify the existing glovebox ports, hose layout and required accessories in the quotation request. Check transfer clearance against the full machine dimensions before installation.
Crimping Dies, Height Stop and Process Selection
The standard configuration is for CR20-series coin cells. Sealing CR16, CR24 or CR30 formats requires suitable optional dies or replacement die components. Disassembly, electrode pressing and powder compaction are separate tooling-dependent applications, not included capabilities of the standard crimping die. Send the case drawing, gasket and internal-stack details to confirm tooling compatibility.
Set the height stop and regulated pressure for the actual case, and validate the finished crimp before processing research samples. Positioning and height-limiting features help control assembly but do not eliminate the risk of short circuits, damaged cases or leakage. This unit is not an electrical short-circuit tester.
Operation and Maintenance
Use trained personnel and keep hands clear of the dies, guide columns and moving plate. Before changing tooling, cleaning or maintenance, isolate the gas supply and fully release stored pressure. Keep the guides and forming surfaces clean, lubricate moving parts as appropriate, and inspect fasteners. Cleaning and lubrication must be compatible with the cell materials and glovebox environment.
Compare Coin Cell Assembly Equipment
For touchscreen-controlled electric operation, see the electric coin cell crimping machine. For a manual alternative, compare the hydraulic coin cell crimper. Prepare electrode and separator discs with the manual coin cell disc punch, and browse coin cell components or coin cell preparation equipment. Confirm die compatibility for the selected case.
Request a Quote
Send the cell format and case drawing, required crimping or disassembly tooling, available gas supply, glovebox exhaust arrangement, quantity and delivery destination. We will confirm the configured machine and accessories and provide a written quotation.
Share

Request a Lab Quote
For institutional purchase orders, non-standard configurations, larger quantities or written shipping terms, send the details below. We will reply before anything is ordered.
Product: Pneumatic Coin Cell Crimping Machine for CR20XX Cells
SKU: FL-QF150
Browse Related Research Categories
-
Battery Separators
Compare battery separator films, membranes and pre-cut discs for laboratory cells. Options...
-
Coin Cell Components
Compare coin cell cases, spacers and springs for laboratory battery assembly. The...
-
Current Collectors & Foils
Browse current collectors and metal substrates for laboratory electrode preparation, including copper...
-
Conductive Additive
Compare conductive carbon blacks and graphite for laboratory battery electrode formulations. Grades...