Skip to product information
1 of 1

Flux Battery Hub

Vacuum Standing Box for Battery Electrolyte Wetting

Vacuum Standing Box for Battery Electrolyte Wetting

SKU:FL-JZ300-110V

  • Formal Quotes & POs
  • DDP to Most Destinations
  • Return Policy Available

This vacuum standing box supports electrolyte wetting in lithium-ion battery laboratory workflows after electrolyte filling. Controlled evacuation and programmable standing periods help remove trapped air and promote electrolyte penetration into the electrode assembly. The split chamber and control-box design supports compatible pouch cell and cylindrical cell research setups.

Vacuum standing chamber and separate controller for pouch and cylindrical battery electrolyte wetting — illustration
Equipment illustration adapted from the machine reference image; final configuration may vary.

Vacuum-Assisted Battery Electrolyte Wetting

  • Programmable standing time and multi-stage cycling for process-development trials.
  • Pneumatically raised and lowered upper chamber with guided motion.
  • Observation window for viewing the chamber during the process.
  • Separate working chamber and controller for flexible laboratory integration.
  • 320 × 220 × 175 mm internal chamber for compatible cells and fixtures.

Use after electrolyte dosing and before the next sealing or assembly step required by your cell process. This equipment is a vacuum standing chamber, not an electrolyte metering pump, heat sealer, vacuum drying oven or formation cycler. Wetting results depend on electrolyte properties, electrode structure, cell geometry and the validated pressure/time sequence.

Technical Specifications

Parameter Specification
Model / SKU FL-JZ300
Application Vacuum-assisted electrolyte wetting after filling, for compatible pouch and cylindrical cells
Internal chamber dimensions (L × W × H) 320 × 220 × 175 mm
Standing / hold time 0–9,999 seconds, adjustable
Vacuum capability Approximately −95 kPa gauge with a suitable external vacuum pump; actual achievable pressure depends on the pump, connections and operating conditions
Reference operating vacuum Approximately −90 kPa gauge
Vacuum retention reference Pressure rise no greater than approximately 1 kPa over 1 minute under the specified sealed-chamber test conditions; confirm test conditions at quotation
Chamber material Aluminum alloy
Power supply AC 220V / 50Hz or AC 110V / 60Hz — select one factory version
Rated electrical power 100 W (machine only; external vacuum pump is separate)
Pneumatic supply pressure 0.5–0.8 MPa
Chamber / motion unit dimensions (L × W × H) Approximately 500 × 350 × 630 mm
Control unit dimensions (L × W × H) Approximately 460 × 350 × 340 mm
Total equipment weight Approximately 50 kg
Vacuum pump Not included; provide a compatible external vacuum source
Protection Safety light curtain and protective enclosure

Vacuum values above are gauge pressures relative to ambient, not absolute pressure. The vacuum pump must be selected for the required pressure, evacuation time and electrolyte-vapor compatibility. Do not treat maximum vacuum capability as the recommended setting for every electrolyte.

Glovebox and Utility Requirements

The split layout allows the chamber to be considered for glovebox installation, subject to verification of the access opening, internal clearance, feedthroughs and exhaust routing. The chamber-unit dimensions are larger than the usable internal chamber dimensions. Confirm physical fit before ordering.

When operated inside a glovebox, the pneumatic drive must use the same compatible working gas as the glovebox atmosphere at 0.5–0.8 MPa. Do not introduce ordinary compressed air into an inert glovebox. Confirm the vacuum pump, exhaust handling, seals and wetted materials for your electrolyte and site procedures. No universal chemical compatibility or explosion-proof rating is claimed.

Choose the Electrical Version

Available as AC 220V / 50Hz or AC 110V / 60Hz. Choose one factory configuration in your quote request; this is not an automatic dual-voltage input. Specify any separate electrical requirements for the external vacuum pump.

Related Battery Assembly Equipment

Explore pouch cell preparation equipment and cylindrical cell preparation equipment for your cell format. For a pouch cell workflow, compare the aluminum laminated film cup forming machine upstream and the vacuum pre-sealing machine for the subsequent sealing stage, as required by your process.

Request a Quote

Send the cell format and dimensions, batch quantity and fixture layout, electrolyte compatibility requirements, target vacuum and hold sequence, available vacuum source, preferred electrical version, glovebox installation details and delivery destination. We will confirm the configured equipment, included accessories and commercial terms by email.

View full details

Request a Lab Quote

For institutional purchase orders, non-standard configurations, larger quantities or written shipping terms, send the details below. We will reply before anything is ordered.

Product: Vacuum Standing Box for Battery Electrolyte Wetting
SKU: FL-JZ300-110V

Submitting this form does not place an order or confirm availability, pricing or delivery. DDP shipping is included for most destinations we serve. Remote, restricted or unsupported destinations may require different terms, which we will confirm before fulfillment.