Pneumatic 18650 Cylindrical Cell Crimping Machine

Pneumatic 18650 Cylindrical Cell Crimping Machine

SKU:FL-QF650

  • Formal Quotes & POs
  • DDP to Most Destinations
  • Return Policy Available

This pneumatic 18650 cylindrical cell crimper uses a gas-driven cylinder and manual valve control for laboratory battery sealing. The standard configuration includes one 18650 die set and uses two sealing stages. It requires no electrical supply and supports externally routed exhaust for a suitably configured glovebox installation.

Pneumatic 18650 cylindrical cell crimping machine with two-step sealing tooling
Representative illustration of the pneumatic 18650 crimper.

Key Features

  • Purely pneumatic operation without an electrical connection.
  • Standard 18650 cylindrical-cell tooling for two-step crimping.
  • Manual valve control of the cylinder-driven sealing motion and regulated gas pressure.
  • Optional die configurations for other cylindrical formats, subject to case and clearance confirmation.
  • Compact benchtop layout with provision for external exhaust routing.

Technical Specifications

Parameter Specification
Model / SKU FL-QF650
Drive Pneumatic cylinder
Electrical supply Not required
Standard die set One 18650 cylindrical-cell sealing set
Sealing sequence Two-step crimping
Argon / nitrogen cylinder supply 0.6–1.0 MPa, regulated
Compressed-air supply 0.7 MPa; not recommended inside a controlled-atmosphere glovebox
Recommended regulated operating pressure 0.7 MPa
Maximum pressure-control setting 1 MPa
Pressure-control reference Within ±0.5%; confirm calibration basis and operating conditions
Gas consumption Approximately 600 mL per sealing operation; reference conditions to be confirmed
Sealing stroke 25 mm
External dimensions (L × W × H) 370 × 240 × 380 mm
Approximate equipment weight 33 kg

The MPa values describe the gas supply and pressure-control circuit, not the contact pressure on the case or the press force in kgf or kN. The 1 MPa control maximum is not a recommended setting for every cell. The gas-consumption value does not establish a full two-stage-cycle consumption or a normalized free-gas volume without reference-condition confirmation. Select pressure and tooling limits for the actual shell, cap and gasket.

18650 Tooling and Two-Step Sealing

The included tooling is for 18650 cases. Other cylindrical formats need an appropriate optional die and confirmation of machine clearances. Supply the case drawing, rim profile, cap and gasket dimensions rather than assuming all cylindrical cells are interchangeable. No additional die sizes are included by default.

Follow the qualified two-stage tooling sequence and confirm any separate rim-grooving requirement in the cell-assembly procedure. This station seals a prepared case; rim grooving is a separate operation. Validate finished crimp dimensions, gasket condition, leakage and isolation using acceptance criteria for the selected assembly.

Glovebox Gas and Exhaust Planning

For controlled-atmosphere work, use a gas compatible with the materials and existing glovebox atmosphere and route the exhaust outside through a suitable sealed connection. Argon and nitrogen are not interchangeable for every chemistry. Do not discharge compressed air into an inert glovebox.

Confirm gas purity, regulator, hose fittings, feedthrough and exhaust layout with the installation requirements. These accessories and a gas cylinder or compressor are not implied to be included. Check transfer clearance, internal space and safe handling for the 370 × 240 × 380 mm, approximately 33 kg unit.

Pneumatic versus Manual Hydraulic Crimping

Choose the pneumatic configuration when a suitable regulated gas supply is available and cylinder-driven motion fits the laboratory workflow. If a hand-operated hydraulic station is preferred, compare the manual 18650 cylindrical cell crimper. Compare the drive, tooling, and pressure requirements before selecting a station.

Operation and Care

Use trained personnel, keep hands clear of moving dies and guides, and do not exceed approved pressure or tooling limits. Isolate the gas supply and fully release stored pressure before changing tooling, cleaning or maintenance. Inspect fittings, fasteners and forming surfaces, and use cleaning methods compatible with the cell materials and glovebox environment. Neither pneumatic actuation nor precision tooling alone guarantees a leak-free or short-circuit-free cell.

Related Cylindrical Cell Assembly Products

For upstream assembly, see the battery electrode winding machine and negative-tab bottom spot welder. Review 18650 stainless-steel case sets and confirm die compatibility. Browse cylindrical cell preparation equipment for separate process stations.

Request a Quote

Send the cell format, case and cap drawings, gasket details, available gas supply, glovebox exhaust requirements, required tooling, quantity and delivery destination. We will confirm the configuration and provide a written quotation.

View full details

Request a Lab Quote

For institutional purchase orders, non-standard configurations, larger quantities or written shipping terms, send the details below. We will reply before anything is ordered.

Product: Pneumatic 18650 Cylindrical Cell Crimping Machine
SKU: FL-QF650

Submitting this form does not place an order or confirm availability, pricing or delivery. DDP shipping is included for most destinations we serve. Remote, restricted or unsupported destinations may require different terms, which we will confirm before fulfillment.